The research was conducted to investigate the performance of old repaired columns inSriwulan Village (Sayung) and Pucang Gading. The performance of 3 columns wasinvestigated by non destructive test and destructive test at age of repaired columns at 12, 13,and 14 months. Non destructive test conducted by Hammer Test while destructive testconducted by Core Drill Test. The results of research has shown that from Hammer Test,highest compressive strength at age 14 months was 45,65 MPa. For Core Drill Test results,the highest compressive strength 73,62 MPa found in Pucang Gading at column 1 at zone A byage 14 months while the lowest at same site and column at zone C 14,22 MPa

Published by Universitas Katolik Soegijapranata
Journal Name G - SMART
Contact Phone-
Contact Name -
Contact Email -
Location Kota semarang, Jawa tengah INDONESIA
Website gsmart| http://journal.unika.ac.id/index.php/gsmart|
ISSN ISSN : 26205297, EISSN : 26205297, DOI : -,
Core Subject Engineering,
Meta Subject Civil Engineering, Building, Construction & Architecture, Engineering, Transportation,
Meta DescJurnal G - SMART : Jurnal Teknik Sipil Unika Soegijapranata yang meliputi Geoteknik, Struktur, Manajemen Konstruksi, Sumber Daya Air dan Transportasi.
PenulisDeniswara, Cindy , Ratomesang, Richardo Pelipus Boru , Susilorini, Rr.M.I. Retno , Santosa, Budi
Publisher ArticleG - SMART
Subtitle Article G - SMART Vol 1, No 2 (2017)
Scholar Googlehttp://scholar.google.com/scholar?q=%2Bintitle%3A&…
View Articlehttp://journal.unika.ac.id/ind…
DOIhttps://doi.org/10.24167/gs.v1i2.12…
DOI Number DOI: 10.24167/gs.v1i2.1266
Download Article [1] http://journal.unika.ac.id/index.php/gsm…
Download Article [2] http://download.garuda.ristekdikti.go.id…

 

Pengukuran kinerja Indikator kinerja Manajemen kinerja Teori kinerja karakteristik Indeks kinerja ilmiah Komputasi kinerja tinggi Kromatografi cair kinerja tinggi Peringkat Universitas berdasarkan Kinerja Akademik KPI Superkomputer