Post-occupancy evaluationPost Occupancy Evaluation (POE) has its origins in Scotland and the United States and has been used in one form or another since the 1960s. Preiser and colleagues define POE as "the process of evaluating buildings in a systematic and rigorous manner after they have been built and occupied for some time". The unique aspect of Post Occupancy Evaluation is that it generates recommendations based on all stakeholder groups' experiences of subject buildings' effects on productivity and wellbeing.[1] Purposes of POEPost Occupancy Evaluations is used to improve the ways that buildings are used to support productivity and wellbeing. Specifically it is used to:
The British Council for Offices (BCO)[2] summarises that a POE provides feedback of how successful the workplace is in supporting the occupying organization and the requirements of individual end-users. The BCO also suggests that POE can be used to assess if a project brief has been met. Furthermore, the BCO recommends that POE is used as part of the Evidence-based design process, where the project usually refers to a building design fit-out or refurbishment, or to inform the project brief where the project is the introduction of a new initiative, system or process. POE usually involves feedback from the building occupants, through questionnaires, interviews and workshops, but may also involve more objective measures such as environmental monitoring, space measurement and cost analysis. Building interest groupsPost Occupancy Evaluations involve all stakeholder groups with interests in the subject buildings. Stakeholders are typically:
Components of POEThe POE process provides value-neutral prompts to stimulate stakeholders to make testable observations about their experiences of buildings' effect on productivity and wellbeing. These observations are clarified and documented by the evaluator. Stakeholders' testable observations will be specific to building design, use and operating conditions and these may involve "negotiation" of all three dimensions of building evaluation to realize the optimum ways of achieving productivity and wellbeing. Recommendations are based on complete set of stakeholders' observations. Most recommendations are to inform planning and design of future new buildings the operational practices. They also generate some recommendations for modifications to the subject buildings and for changes in the ways that they are used. POE evaluators may recommend monitoring, research, investigation or project management studies. Some POE include other building studies. POE incorporate may include quantitative and qualitative techniques. Most POEs will involve seeking feedback from the occupants of the place being evaluated; this may be achieved through various survey methodology including questionnaire, interview or focus group. The occupant feedback may be supplemented by environmental monitoring, such as temperature, noise levels, lighting levels and indoor air quality. More recently, POEs tend to include sustainable measures such as energy consumption, waste levels, and water usage. Other commonly used quantitative measures include space metrics, for example occupational density, space utilization and tenant efficiency ratio. Cost, either expressed as the cost of the project per square meter or the total cost of occupancy, is considered a key metric in building evaluation and may be compared with the occupant feedback to provide a better understanding of value. Certification schemeBoth LEED and WELL consider occupant surveys as part of their certification scheme. LEED v4IEQ survey, as a part of POE, is involved in LEED certification scheme v4. For all LEED O+M projects using LEED v4, one point (EQ Credit: Occupant Comfort Survey) can be awarded to those who intents to assess building occupants' comfort.[3] WELL v2WELL involves the occupant survey in both preconditions[4] and optimization[5] features in the concept of community. Besides, it has a particular feature related to occupant survey on thermal comfort concept.[6] Occupant SurveyOccupant Survey (Feature C03) is one of the precondition features of the community concept, which means it is mandatory for certification. This feature intends to establish minimum standards for the evaluation of experience and self-reported health and well-being of building occupants. The requirements of this feature are the following two parts:[4]
Enhanced Occupant SurveyEnhanced Occupant Survey (Feature C04) is an optimization feature of community concept, which helps to achieve WELL certification. The purpose of this feature is to evaluate comfort, satisfaction, behavior change, self-reported health and other robust factors related to the well-being of occupants in buildings. A project can have up to 3 points it meets below requirements:[5]
Enhanced Thermal PerformanceEnhanced Thermal Performance (Feature T02) is one of the optimization features of thermal comfort concept. This feature aims to enhance thermal comfort and promote human productivity by ensuring that a substantial majority of building users (above 80%) perceive their environment as thermally acceptable. The maximum points are three, and there are achieved by following parts:[6]
POE at any stage after building occupancyThe term "post occupancy" can be confusing and simply refers to an occupied building rather than a vacant one. Furthermore, POEs may be conducted at regular intervals to monitor how the building facilities and its operation are currently supporting the occupants. A pre-project POE may be used to:
A POE is often carried out six to twelve months after construction work is complete and buildings are occupied. Post Occupancy Evaluations are also undertaken at any time buildings' "lives"; particularly to understand stakeholders' experience of them, for briefing alterations and changes. Any built environment accommodating peoplePOE's have been conducted of facilities for schools, universities, technical institutes, kindergartens, museums, offices, courts, corrections, military, hospitals,[7] landscape/civil works, learning environments,[8] libraries,[9][10] jails,[11] police stations,[12] housing,[13] health centres[14] and zoos.[15] It would be equally possible to apply POE techniques to ships and "virtual" environments. POE has been applied to selected parts of buildings, aspects of buildings and groups of buildings on the same campus and several sites. Independent evaluationPOE is usually carried out by architects or building professionals with a social science or workplace consulting background. POE by independent consultants can offer an impartial evaluation. Other building studiesPOE can be informed by reference to other building studies and POEs sometimes recommend other studies such as: