ISO 10993The ISO 10993 set entails a series of standards for evaluating the biocompatibility of medical devices to manage biological risk. These documents were preceded by the Tripartite agreement and is a part of the international harmonisation of the safe use evaluation of medical devices.[1] For the purpose of the ISO 10993 family of standards, biocompatibility is defined as the "ability of a medical device or material to perform with an appropriate host response in a specific application". ISO 10993-1:2009 & FDA endpoints for considerationThe following table provides a framework for the development of a biocompatibility evaluation. Different biological endpoints may require evaluation for particular medical devices, including either additional or fewer endpoints than indicated. If it is unclear in which category a device falls, consulting device-specific guidances or contacting the appropriate US Food and Drug Administration (FDA) review division for more information is possible. The table "Endpoints to be addressed in a biological risk assessment" was revised by the 2018 edition of ISO 10993-1. The selection of endpoints for the biocompatibility evaluation is determined by the nature of body contact (e.g. implant device) and contact duration (e.g. long term contact of more than 30 days).
List of the standards in the 10993 seriesPart 1: Evaluation and testing within a risk management process Part 2: Animal welfare requirements Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity Part 4: Selection of tests for interactions with blood Part 5: Tests for in vitro cytotoxicity. Part 6: Tests for local effects after implantation Part 7: Ethylene oxide sterilization residuals Part 8: Selection of reference materials (withdrawn) Part 9: Framework for identification and quantification of potential degradation products Part 10: Tests for skin sensitization Part 11: Tests for systemic toxicity Part 12: Sample preparation and reference materials (available in English only) Part 13: Identification and quantification of degradation products from polymeric medical devices Part 14: Identification and quantification of degradation products from ceramics Part 15: Identification and quantification of degradation products from metals and alloys Part 16: Toxicokinetic study design for degradation products and leachables Part 17: Establishment of allowable limits for leachable substances Part 18: Chemical characterization of medical device materials within a risk management process Part 19: Physico-chemical, morphological and topographical characterization of materials Part 20: Principles and methods for immunotoxicology testing of medical devices Part 22: Guidance on nanomaterials Part 23: Tests for irritation Part 33: Guidance on tests to evaluate genotoxicity See alsoReferences
|