Geiger counter
A Geiger counter (/ˈɡaɪɡər/, GY-gər;[1] also known as a Geiger–Müller counter or G-M counter) is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental physics and the nuclear industry. "Geiger counter" is often used generically to refer to any form of dosimeter (or, radiation-measuring device), but scientifically, a Geiger counter is only one specific type of dosimeter. It detects ionizing radiation such as alpha particles, beta particles, and gamma rays using the ionization effect produced in a Geiger–Müller tube, which gives its name to the instrument.[2] In wide and prominent use as a hand-held radiation survey instrument, it is perhaps one of the world's best-known radiation detection instruments. The original detection principle was realized in 1908 at the University of Manchester,[3] but it was not until the development of the Geiger–Müller tube in 1928 that the Geiger counter could be produced as a practical instrument. Since then, it has been very popular due to its robust sensing element and relatively low cost. However, there are limitations in measuring high radiation rates and the energy of incident radiation.[4] The Geiger counter is one of the first examples of data sonification.[5] Principle of operationA Geiger counter consists of a Geiger–Müller tube (the sensing element which detects the radiation) and the processing electronics, which display the result. The Geiger–Müller tube is filled with an inert gas such as helium, neon, or argon at low pressure, to which a high voltage is applied. The tube briefly conducts electrical charge when high energy particles or gamma radiation make the gas conductive by ionization. The ionization is considerably amplified within the tube by the Townsend discharge effect to produce an easily measured detection pulse, which is fed to the processing and display electronics. This large pulse from the tube makes the Geiger counter relatively cheap to manufacture, as the subsequent electronics are greatly simplified.[4] The electronics also generate the high voltage, typically 400–900 volts, that has to be applied to the Geiger–Müller tube to enable its operation. This voltage must be carefully selected, as too high a voltage will allow for continuous discharge, damaging the instrument and invalidating the results. Conversely, too low a voltage will result in an electric field that is too weak to generate a current pulse.[6] The correct voltage is usually specified by the manufacturer. To help quickly terminate each discharge in the tube a small amount of halogen gas or organic material known as a quenching mixture is added to the fill gas. ReadoutThere are two types of detected radiation readout: counts and radiation dose.
The readout can be analog or digital, and modern instruments offer serial communications with a host computer or network. There is usually an option to produce audible clicks representing the number of ionization events detected. This is the distinctive sound associated with handheld or portable Geiger counters. The purpose of this is to allow the user to concentrate on manipulation of the instrument while retaining auditory feedback on the radiation rate. LimitationsThere are two main limitations of the Geiger counter:
Types and applicationsThe intended detection application of a Geiger counter dictates the tube design used. Consequently, there are a great many designs, but they can be generally categorized as "end-window", windowless "thin-walled", "thick-walled", and sometimes hybrids of these types. Particle detectionThe first historical uses of the Geiger principle were to detect α- and β-particles, and the instrument is still used for this purpose today. For α-particles and low energy β-particles, the "end-window" type of a Geiger–Müller tube has to be used, as these particles have a limited range and are easily stopped by a solid material. Therefore, the tube requires a window which is thin enough to allow as many as possible of these particles through to the fill gas. The window is usually made of mica with a density of about 1.5–2.0 mg/cm2.[2] α-particles have the shortest range, and to detect these the window should ideally be within 10 mm of the radiation source due to α-particle attenuation.[2] However, the Geiger–Müller tube produces a pulse output which is the same magnitude for all detected radiation, so a Geiger counter with an end window tube cannot distinguish between α- and β-particles.[4] A skilled operator can use varying distance from a radiation source to differentiate between α- and high energy β-particles. The "pancake" Geiger–Müller tube is a variant of the end-window probe, but designed with a larger detection area to make checking quicker. However, the pressure of the atmosphere against the low pressure of the fill gas limits the window size due to the limited strength of the window membrane. Some β-particles can also be detected by a thin-walled "windowless" Geiger–Müller tube, which has no end-window, but allows high energy β-particles to pass through the tube walls. Although the tube walls have a greater stopping power than a thin end-window, they still allow these more energetic particles to reach the fill gas.[2] End-window Geiger counters are still used as a general purpose, portable, radioactive contamination measurement and detection instrument, owing to their relatively low cost, robustness and relatively high detection efficiency; particularly with high energy β-particles.[4][7] However, for discrimination between α- and β-particles or provision of particle energy information, scintillation counters or proportional counters should be used.[8] Those instrument types are manufactured with much larger detector areas, which means that checking for surface contamination is quicker than with a Geiger counter. Gamma and X-ray detectionGeiger counters are widely used to detect gamma radiation and X-rays, collectively known as photons, and for this the windowless tube is used. However, detection efficiency is low compared to alpha and beta particles. The article on the Geiger–Müller tube carries a more detailed account of the techniques used to detect photon radiation. For high energy photons, the tube relies on the interaction of the radiation with the tube wall, usually a material with a high atomic number such as stainless steel of 1–2 mm thickness, to produce free electrons within the tube wall, due to the photoelectric effect. If these migrate out of the tube wall, they enter and ionize the fill gas.[4] This effect increases the detection efficiency because the low-pressure gas in the tube has poorer interaction with higher energy photons than a steel tube. However, as photon energies decrease to low levels, there is greater gas interaction, and the contribution of direct gas interaction increases. At very low energies (less than 25 keV), direct gas ionisation dominates, and a steel tube attenuates the incident photons. Consequently, at these energies, a typical tube design is a long tube with a thin wall which has a larger gas volume, to give an increased chance of direct interaction of a particle with the fill gas.[2] Above these low energy levels, there is a considerable variance in response to different photon energies of the same intensity, and a steel-walled tube employs what is known as "energy compensation" in the form of filter rings around the naked tube, which attempts to compensate for these variations over a large energy range.[2] A steel-walled Geiger–Müller tube is about 1% efficient over a wide range of energies.[2] Neutron detectionA variation of the Geiger tube known as a Bonner sphere can be used to exclusively measure radiation dosage from neutrons rather than from gammas by the process of neutron capture. The tube, which can contain the fill gas boron trifluoride or helium-3, is surrounded by a plastic moderator that reduces neutron energies prior to capture. When a capture occurs in the fill gas, the energy released is registered in the detector. Gamma measurement—personnel protection and process controlWhile "Geiger counter" is practically synonymous with the hand-held variety, the Geiger principle is in wide use in installed "area gamma" alarms for personnel protection, as well as in process measurement and interlock applications. The processing electronics of such installations have a higher degree of sophistication and reliability than those of hand-held meters. Physical designFor hand-held units there are two fundamental physical configurations: the "integral" unit with both detector and electronics in the same unit, and the "two-piece" design which has a separate detector probe and an electronics module connected by a short cable. In the 1930s a mica window was added to the cylindrical design allowing low-penetration radiation to pass through with ease.[9] The integral unit allows single-handed operation, so the operator can use the other hand for personal security in challenging monitoring positions, but the two piece design allows easier manipulation of the detector, and is commonly used for alpha and beta surface contamination monitoring where careful manipulation of the probe is required or the weight of the electronics module would make operation unwieldy. A number of different sized detectors are available to suit particular situations, such as placing the probe in small apertures or confined spaces. Gamma and X-Ray detectors generally use an "integral" design so the Geiger–Müller tube is conveniently within the electronics enclosure. This can easily be achieved because the casing usually has little attenuation, and is employed in ambient gamma measurements where distance from the source of radiation is not a significant factor. However, to facilitate more localised measurements such as "surface dose", the position of the tube in the enclosure is sometimes indicated by targets on the enclosure so an accurate measurement can be made with the tube at the correct orientation and a known distance from the surface. There is a particular type of gamma instrument known as a "hot spot" detector which has the detector tube on the end of a long pole or flexible conduit. These are used to measure high radiation gamma locations whilst protecting the operator by means of distance shielding. Particle detection of alpha and beta can be used in both integral and two-piece designs. A pancake probe (for alpha/beta) is generally used to increase the area of detection in two-piece instruments whilst being relatively light weight. In integral instruments using an end window tube there is a window in the body of the casing to prevent shielding of particles. There are also hybrid instruments which have a separate probe for particle detection and a gamma detection tube within the electronics module. The detectors are switchable by the operator, depending the radiation type that is being measured. Guidance on application useIn the United Kingdom the National Radiological Protection Board issued a user guidance note on selecting the best portable instrument type for the radiation measurement application concerned.[8] This covers all radiation protection instrument technologies and includes a guide to the use of G-M detectors. HistoryIn 1908 Hans Geiger, under the supervision of Ernest Rutherford at the Victoria University of Manchester (now the University of Manchester), developed an experimental technique for detecting alpha particles that would later be used to develop the Geiger–Müller tube in 1928.[10] This early counter was only capable of detecting alpha particles and was part of a larger experimental apparatus. The fundamental ionization mechanism used was discovered by John Sealy Townsend between 1897 and 1901,[11] and is known as the Townsend discharge, which is the ionization of molecules by ion impact. It was not until 1928 that Geiger and Walther Müller (a PhD student of Geiger) developed the sealed Geiger–Müller tube which used basic ionization principles previously used experimentally. Small and rugged, not only could it detect alpha and beta radiation as prior models had done, but also gamma radiation.[9][12] Now a practical radiation instrument could be produced relatively cheaply, and so the Geiger counter was born. As the tube output required little electronic processing, a distinct advantage in the thermionic valve era due to minimal valve count and low power consumption, the instrument achieved great popularity as a portable radiation detector. Modern versions of the Geiger counter use halogen quench gases, a technique invented in 1947 by Sidney H. Liebson.[13] Halogen compounds have superseded the organic quench gases because of their much longer life and lower operating voltages; typically 400-900 volts.[14] Gallery
See also
References
External linksMedia related to Geiger counters at Wikimedia Commons |